Title
How External Contact/Signal can be received by Camera
Brands
Summary
Environment
Ulisse 2
Issue
We have an external signal (dry contact), that we intend to be received by the camera alarm input. Is there a terminal in the Ulisse2 "connector board" that can be used, that will translate to a signal/contact/relay activation in the "housing board?
Resolution
You can use the I/O connector J3 in the connector board in the base.
Connect the signal to one of input, then, from the web page, select the correct input ID through "Digital Inputs" submenù and set "Action" as DNHOUSING
Connect the input of the camera to the DN1/DN2 terminals of connector J14 in the housing board
Cause
Customer want to bring an external signal to the third-party camera input installed in the Ulisse2 housing
Comments