UPT - WASPT: connection diagram

These connection diagrams depict how the WASPT must be connected to the Ulisse (UPT).

Different version for the UPT are available (Analog, Netcam); the diagrams report the base board's terminal to be used for Pump Control and Water Level Alarm (not available on the Netcam versions equipped with IR Illuminators).

The Washer control is achieved by the means of an integrated Relay Out, while the Wiper is internally controlled by the unit itself.

The Netcam version has a different electronics behind the alarm line compared to the Analog version (Netcam: Self-Powered; Analog: Externally-Powered), so different terminals must be used on the WASPT side.

Be sure to configure the WASPT for the voltage level used by the UPT (24, 120, or 230VAC).