HOUSINGS: connection diagrams

HOV/HGV - WASPT

This configuration allows the user to control the Wiper and the Washer from the Camera's web pages or from the VMS.

The IPM housings do not provide the wiper due to PoE+ power limitations. Should a wiper be necessary, a standard housing must be used.

Depending on the camera capabilities, Wiper and Washer control can be achieved from the Camera's Relays, or from the Telemetry Serial Out over RS485 (Pelco-D protocol). In the second option, the WASPT must be equipped with the optional Telemetry Receiver (DTWRX).

 

Diapositiva1.JPG

Diapositiva2.JPG

Diapositiva3.JPG

Additional Notes about the Camera

Depending on the system composition, it is necessary to verify if the camera's Digital Outputs can be operated from the selected control interface (Web Browser, VMS Client), or if the camera is able to forward the expected telemetry commands on the Serial Port, in order to activate/deactivate the wiper and the washer pump.

When a VMS is used:

  • in case of Relay Control (diagram 1 & 2), the VMS Client must provide suitable controls to open/close the camera's relays;
  • in case of Telemetry Control (diagram 3), the VMS Client must provide suitable controls to send either Auxiliary commands or Set Preset commands to the Camera, and the Camera must put it on the Serial Port, to let them reach the DTWRX.
    It is strongly advised to verify if such commands are correctly forwarded by the Camera, using a Protocol Analyzer connected to the Camera's Serial Port, activating the proper controls from the VMS Client.
    Aux controls are not common on VMS, and sometime the VMS Client provides GoTo Preset controls only, making the Set Preset controls available on the Administration interface only.

The following table reports the telemetry commands supported by the DTWRX, which the camera has to provide:

Operation Command Pelco-D string
Wiper Start AUX 3 ON FF 01 00 09 00 03 0D
SET PRESET 85 FF 01 00 03 00 55 59
Wiper Stop AUX 3 OFF FF 01 00 0B 00 03 0F
SET PRESET 86 FF 01 00 03 00 56 5A
Washer Start AUX 4 ON FF 01 00 09 00 04 0E
SET PRESET 87 FF 01 00 03 00 57 5B
Washer Stop AUX 4 OFF FF 01 00 0B 00 04 10
SET PRESET 97 FF 01 00 03 00 61 65

 

Also, some VMS do not provide the mentioned controls, but they allow the configuration of custom commands on the device; this feature can be used to send the Camera special CGI-BIN commands, usually in the URL format; for example:

http://192.168.0.100/cgi-bin/ptz.cgi?savepresetno=85
http://192.168.0.100/cgi.bin/ptz.cgi?auxiliary=setaux3

Check with the Camera manufacturer whether CGI-BIN commands are available for your Camera.

 

 

HOV - WAS

This configuration allows the user to control the Wiper and the Washer from the Camera's web pages or from the VMS.

The IPM housings do not provide the wiper due to PoE+ power limitations. Should a wiper be necessary, a standard housing must be used.

 

Diapositiva1.JPG

Diapositiva2.JPG

Additional Notes about the Camera

Depending on the system composition, it is necessary to verify if the camera's Digital Outputs can be operated from the selected control interface (Web Browser, VMS Client) in order to activate/deactivate the wiper and the washer pump.

When a VMS is used, the VMS Client must provide suitable controls to open/close the camera's relays. 

 

MHX - WASEX

This connection diagram depicts how the WASEX's valve must be connected to the MHX housing, for different voltage levels which the housing is fed with.

The Washer control is achieved by the means of an integrated Relay Out, while the Wiper is internally controlled by the unit itself.

In any case, it necessary to use a suitable insulation transformer, in order to disjoin the valve from the power network.

WARNING: the Insulation Transformer must be installed either inside an explosion-proof box, or in a safe zone out from the classified area.

 

Diapositiva1.JPG

Diapositiva2.JPG

Diapositiva3.JPG

Diapositiva4.JPG

 

NXM/NXL - VIPNX - WASNX/WASPT

These connections diagrams illustrates how the WASEX or the WASPT must be connected to the NXM/NXL housing.

It also shows how to connect the VIPNX external wiper.

 

Diapositiva1.JPG

Diapositiva1.JPG

 